Table 18 – Hydrometer Temperature Corrections

T °C

Delta G

T °F

T °C

Delta G

T °F

0

-0.0007

32.00

25

0.0021

77.00

1

-0.0008

33.80

26

0.0023

78.80

2

-0.0008

35.60

27

0.0026

80.60

3

-0.0009

37.40

28

0.0029

82.40

4

-0.0009

39.20

29

0.0032

84.20

5

-0.0009

41.00

30

0.0035

86.00

6

-0.0008

42.80

31

0.0038

87.80

7

-0.0008

44.60

32

0.0041

89.60

8

-0.0007

46.40

33

0.0044

91.40

9

-0.0007

48.20

34

0.0047

93.20

10

-0.0006

50.00

35

0.0051

95.00

11

-0.0005

51.80

36

0.0054

96.80

12

-0.0004

53.60

37

0.0058

98.60

13

-0.0003

55.40

38

0.0061

100.40

14

-0.0001

57.20

39

0.0065

102.20

15

0

59.00

40

0.0069

104.00

16

0.0002

60.80

41

0.0073

105.80

17

0.0003

62.60

42

0.0077

107.60

18

0.0005

64.40

43

0.0081

109.40

19

0.0007

66.20

44

0.0085

111.20

20

0.0009

68.00

45

0.0089

113.00

21

0.0011

69.80

46

0.0093

114.80

22

0.0013

71.60

47

0.0097

116.60

23

0.0016

73.40

48

0.0102

118.40

24

0.0018

75.20

49

0.0106

120.20
Advertisements
Categories: calculators
  1. No comments yet.
  1. No trackbacks yet.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: